The base frame consists of three mounting pads connected with structural beams. The
mounting pads shall be connected to the floor using cast in tie rods or adhesive anchors. The
maximum fastenable thickness of 70 mm allows for a maximum grouting thickness of 45 mm.
The floor has to provide sufficient strength, stiffness and stability to support the Motion
System under all conditions. The location of the mounting pads on the floor and the drill
pattern of the mounting pads are shown in Figure 4-3 en Figure 4-4